Casio PA-2500 Specifications Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
— 2 —
No. Length (L) Angle (A)
1 L = 80 cm A = ±15 degree
2 L = 10 cm A = 0 degree
A
L
PA-2500U
PA-2500U
Electrical Specifications
Current Consumption (V-in: 2.6 V ± 0.1 V, LCD Contrast VR: MID.):
Main Battery: Diagnostics Program with alkaline batteries
80 MHz: 650 mA or under
Sleep: 50 mA or under
Standby: 1.4 mA or under
Back-up Battery: OFF: 450 µA
Voltage Detectors:
VDET1: 2.0 V ± 1% V or under (Low battery message detector for alkaline batteries)
VDET2: 1.6 V ± 1% V or under (Foced power off detector for alkaline batteries)
VDET1R: 3.3 V ± 2% V or under (Low battery message detector for rechargeable battery)
VDET2R: 3.0 V ± 2% V or under (Foced power off detector for rechargeable battery)
VDETS: 2.7 V ± 1% V or under (Low battery message detector for back-up battery)
IrDA:
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 79 80

Comments to this Manuals

No comments