— 16 —
QV-10
Set
Oscilloscope
Input
CP101
Pattern
generator
Output
CP410
0 ± 0.25 [V]
6.0 ± 0.1 [V]
QV-10
Set
Input
DC Jack
Regulated
power
supply
Output
CP111
Voltmeter
5.0 ± 0.05 V
QV-10
Set
Input
DC Jack
Regulated
power
supply
Output
CP108
Voltmeter
5.0 ± 0.05 V
VCC2 Voltage Setting
Equipment Connection / Adjustment Procedure
Input Input Input Output Output
Connection Point Signal Connection Point
Adjust Result
Adjust for 4.50 ± 0.02 V
reading on voltmeter.
VR100
Voltmeter CP108
VBL Voltage Setting
Adjust for 5.0 ± 0.05 V
reading on voltmeter.
VR101 Voltmeter CP111
Vcom Adjustment
Color bar
45.75 MHz
CP101 Oscilloscope CP410
Pattern
generator
VR303
VR302
Adjust VR303 so that square-
wave to read 6.0 ± 0.1 V.
Adjust VR302 so that high level
of the square-wave is at 0.0 ±
0.25 V.
QV-30
QV-30
QV-30