— 52 —
Voltage Write-> Contacts Key
Escape -> ON Key
If the unit can not read the voltage 4.2V correctly, "No Good. Please retry!!" message will appear.
Note that the unit can not be progressed in the next stage whenever this message appears.
8. Make the voltage power supply added to the main battery terminal 3.7V ± 0.05V.
Then, press Contacts button again.
Doing so, the following display appears.
*** <AD Revision Value Write> ***
<Max Level Write>
AD Value Read! 0x8...
<Min Level Write>
AD Value Read! 0x8...
WriteData Value
Max=0x....
Min=0x....
---------- Test END
Push Action Key
9. Pressing Action Control button, the following display appears along with Main Menu display
(under Main Menu display).
AD Code=OOOOO
CPROG Rev.0.95 for JX-590/597
If missed, the following # display will appear instead of O.
AD Code=# # # # #
CPROG Rev.0.95 for JX-590/597
If the display appears, be sure to try to perform these settings (adjustments) again.
After turning off the unit power, stop to add the powers to the unit.
Finally, after connecting the rechargeable main battery and AC adapter to the unit, perform Initial
Setup or FULL RESET.