34
Part V
Parameter List
How to Read the Tables
Number Base Notation
“Size” indicates the parameter value bit width as a decimal value.
The bit field position of “Block” as a decimal value.
Values used in the explanations under “Description” are all decimal values, unless specified otherwise.
Values other than those described above are all hexadecimal.
R/W field
The R/W field indicates whether an IPR (Individual Parameter Request) read operation or IPS (Individual Parameter Send)
write operation is enabled.
18 System Parameters
These parameters make it possible for an external device to check the status of the Instrument and for an external device
to command some operation of the Instrument.
18.1 System Information Parameter
This parameter is a container for system information.
19 Setup Parameter
Setup Parameters put a device into the setup mode.
19.1 MIDI Parameter
Parameter ID R/W Block Size Array Min-Def-Max Description
Model 0000 R 000000 7 01 00-00-7F 0...PX-130
1...PX-330
2...PX-730/PX-7
3...PX-830
4...reserved
5...AP-220
6...AP-420
7...AP-620/AP-6
8...PX-3
Parameter ID R/W Block Size Array Min-Def-Max Description
Midi Device Id 006D R/W 000000 7 01 00-7F-7F 0-127
Comments to this Manuals