Casio CE-7000 Service Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 119
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
- 28 -
3. In-line connection
1) System connection diagram
The maximum In-line (ARCNET) cable length and maximum connection unit will be
varied by the In-line communication speed as shown below:
NOTE: The terminater 100 ohms is necessary to mount at the end of In-line cable .
In line communication speed Maximum Maximum
(Baud rate) connection unit cable length A ( m )
312.5 K bps 20 units 430 m
156.25 K bps 32 units 890 m
Terminater (100 ohms) Terminater (100 ohms)
2) In-line cable and connector
CASIO TECHNO will supply the In-line cable, connector and terminater parts by the
following parts code.
In line cable
Code No. Parts name Specification
1904 4023 In-line cable IPEV-SLA0.5x1P
In line connector
Code No. Parts name Specification
3500 5820 In-line connector kit XLP-KIT-1
Terminater
Code No. Parts name Specification
2600 2516 Carbon film resistor R-25-100-J
Signal Pin
SD 1
RD 2
FG FG plate
(In-line connector)
3) In-line cable connection
In-line cable connection diagram is shown below:
Mount the terminater 100 ohms at the both end of In-line cable.
Signal Pin
SD 1
RD 2
FG FG plate
(In-line connector)
Signal Pin
SD 1
RD 2
FG FG plate
(In-line connector)
Terminater
100 ohms
Terminater
100 ohms
Total In-line cable length is max. A m.
Page view 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 118 119

Comments to this Manuals