3.9 Touch Panel Calibration
Function
Adjusts the calibration of touch panel. If an inconsistency is noted between the target position and
the position actually touched on the touch panel, correct it by performing this calibration adjustment.
Fig. 3.8
Operation
Adjustment of the calibration :
First make sure that the arrow points to
in the upper left corner of the screen, then touch
the center of this
with the stylus provided.
When the buzzer sounds, release the stylus from the touch panel.
After the
in the upper left corner disappears and the arrow moves to the in the upper
right corner, touch it in the same way.
Do the same for the
s in the lower left and lower right corners.
When all four
s are touched by the stylus, the touch panel calibration is completed.
If any improper operation has been done, press the “1” key to perform the touch panel
calibration again.
If the “2” key is pressed after the four positions have been touched, the calibration
adjustment result takes effect and the menu screen is restored.
If the “ 2 “ key is pressed before finishing on the fourth position, the adjustment process
performed so far will be canceled.