4. Quality References
This chapter describes about references of the terminal and its dedicated major options concerned with
environmental performance, compliance, mechanical and electric durability, etc.
4.1 Environmental Performances
4.1.1 IT-3000
Table 4.1
Item Specification Condition
Operation
-20 to 50
0 to 40
while mounting
on Cradle. Note 1
0 to 50
HS360, ODT70TC-RAK,
F200UW6, AFP235
For quality print
5 to 35
HG56S, TLC00
Temperature
Non-operation
-20to 70
Operation 10 % to 80 %RH No condensation
Humidity
Non-operation 5% to 90 %RH No condensation
Storage in carton box
Temperature
-20
to 60
Humidity 90 %RH or less
Dust and water-splash proof
IP54 level (compliant with IEC60529)
See “IP (Industrial Protection) code”.
Notes 2 and 3
Notes:
1. It is recommended to check the print quality in the environment including at low temperature where the
terminal is operated before starting the use.
2. IP (Industrial Protection) code
A cording system to indicate the degrees of protection provided by an enclosure against access to hazardous
parts, ingress of solid foreign objects, ingress of water and to give additional protection in connection with
such protection. Elements of the IP54 level and their meanings are as follows.
IP5x;
Represents dust proof to level 5. This level of IP code means that the terminal is protected against solid
foreign objects including dust to penetrate the enclosure.
IPx4;
Represents water-splash proof to level 4. No detrimental effect is observed even with exposure to water
splashed from any direction.
3. All covers on the terminal must be closed.