— 21 —
5-5. Operation of each test
[ 1 ] BATCH TEST 1
[Function]
RAM READ/WRITE test, Watch, buzzer test and drawer open test are performed continuously.
[Operation]
Operation : 1 SUB TOTAL
The following tests are performed automatically.
(1) RAM test: WRITE/READ area test.
(2) Test print
(3) Time setting: Set the following data.
Arranged data: 2005 December 31,23:59'30
(4) Buzzer: Ring once the one shot buzzer.
No print or display in this test.
(5) Drawer open: Drawer 1 opens only.
(6) Receipt issuance
[Print]
*Test print is also done on the journal side.
*If no journal printers are available, “BBBBBBBBBBBBBBBBBBBBBBBB” is printed out on the receipt.
[ 2 ] BATCH TEST 2
[Function]
Display test and LCD backlight test are performed continuously.
[Operation]
Operation : 2 SUB TOTAL
The following tests are performed automatically.
(1) Display test: Press any key to go to the next screen.
(2) LCD pattern test
(3) 7 segment test
(4) LCD backlight test Press any key to switch ON/OFF.
[Print]