— 20 —
10. DIAGNOSTIC OPERATION
2. Display check
DISP CHNG key : Return to menu display
MENU DISPLAY
1 : LCD ALIGNING
2 : ALL DOTS ON
3 : ALTERNATIVE
4 : REVERSE
5 : LCD FRAMING
CASIO 1993. 11. 09
LCD ALIGNING: Lights on dot at corners
ALL DOTS ON : Lights on in all dots (black screen)
ALTERNATIVE : Checker display
REVERSE : Reverse checker display
LCD FRAMING : Lights on dot along the screen edge (frame)
1. Diagnostic mode
The diagnostic mode appears when main switch is turned on
while there is a short in the checkpad. After this operation,
the machine will beep and display "SELF-TEST".
The menu appears after press SET key. Tests are conducted
by selecting the mode from the list on screen. The each test
can be selected by numeral keys.
SELF TEST PROG.
PRESS SET
QUIT BY OFF
CASIO 1993. 11. 09
MENU TOP SHEET
1 : DISP CHECK
2 : RAM TEST
3 : MEMORY TEST
4 : KEY / BUZZER
5 : INTERFACE
CASIO 1993. 11. 09
DISPLAY TEST : Test the LCD disply
RAM TEST : Test the RAM chip
MEMORY TEST : Test the ROM/Clock
KEY/BUZZER : Test all keys and Buzzer
INTERFACE : Test the transmission
Check pad
Main switch