Casio QV-770 Specifications Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
— 20 —
TINT adjustment
• Signal contents
Input oscillation level 0.5 Vp-p to VIDEO terminal (CP302).
• Set power supply
VCL0 (CP101) to 5.0 ± 0.05V.
Apply 3.3 V ± 5 % to PW.
Input HDB signal by connecting PCB-LB.
(You can use an AC adaptor however, for the checking after repairs, apply above mentioned voltages.)
(1) Adjust VR301 so that the second and third pulses of VB (CP324) signal level will be the same.
Notes: • Perform this adjustment after contrast adjustment.
• Trigger FRP (CP305).
VCL0
QV-770
PCB-LA
(CP324)
VB
3.3 V
PW
(CP302)
(CP101)
S G
Power
suppry
VIDEO
(0.5 Vp-p)
1 2 3 4
oscilloscope
Page view 21