— 25 —
7. Disassembly of Camera Unit.
Unscrew one screw (S1), then disassemble as shown.
When assembling convex part of CCD should be placed with concave part of F knob.
Unscrew one screw (S3) and disconnect two flexible cables, them remove CCD unit.
one screw (S1)
one screw (S3)
convex part concave part