— 4 —
QV-770
AD-C620
Block CCD completely from light.
1-2. Defect correct
When there is a blurred black dot in a white display it is called a defect.
To correct this use the data next to this.
• Perform this adjustment after loading color parameters.
(1) Set QV-770 to “REC” mode.
(2) Start test program. (Refer to “1-8. Test program”.)
(3) Choose “DEFECT CORRECT” from test program and execute.
(4) Make sure “ ” mark on LCD turns from red to blue.
(5) Turn power off.
Notes: • Make sure no light goes through CCD.
• As the adjustment data is written in the EEPROM by the POWER switch operation, do not forget
to turn it off using the switch.
• Pixel compensations are performed up to two pixel defects.
• The compensation data is deleted once you exit the mode.
1-3. Strobe adjust
Execute after replacing strobe and loading color parameter, because strobe adjustment informations are
deleted.
• Loading color parameter and Defect correct should be done before.
• Distance between strobe lens and gray paper should be one meter.
• The adjustment must be done in a dark room.
• For gray paper use Superior Oxford Gray No.22. (Note: Use lighter color surface of the paper.)
• The two sizes listed below are available as spare parts. (Can also found in camera store.)
• For power supply use AC adapter.
(1) Set QV-770 to “REC” mode.
(2) Start test program. (Refer to “1-8. Test program”.)
(3) Choose “Strobe adjust” from test program and execute.
(4) Shoot a picture of a specified gray paper. Flash icon should be red before shooting.
(5) Make sure that the flash icon on LCD turns from red to blue.
(6) Turn power off.
Note: As the adjustment data is written in the “EEPROM” by the “POWER” switch operation, do not forget
to turn it off using the switch.
Code No. Name Specification
1904 5411 Gray paper of Superior Oxford No.22 (1.75 × 2.7 m)
1904 5412 Gray paper of Superior Oxford No.22 (2.72 × 11 m)
Comments to this Manuals