Casio XW-G1 User Manual Page 91

  • Download
  • Add to my manuals
  • Print
  • Page
    / 111
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 90
Note1 : For information about the relationship between setting values and send/receive values, see “39.15 LFO Wave Form3
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
Note2 : For information about the relationship between setting values and send/receive values, see the “39.2 –64 - 0 - +63
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
38.13 Tremolo
Parameter Number Parameter Name Value Notes
Parameter7[1] LFO Rate 00 - 7F
Parameter7[2] LFO Depth 00 - 7F
Parameter7[3] LFOWaveform 00 - 7F Note1
Note1 : For information about the relationship between setting values and send/receive values, see “39.15 LFO Wave Form3
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
38.14 Phaser
Parameter Number Parameter Name Value Notes
Parameter7[1] Resonance 00 - 7F
Parameter7[2] LFO Rate 00 - 7F
Parameter7[3] LFO Depth 00 - 7F
Parameter7[4] LFOWaveform 00 - 7F Note1
Note1 : For information about the relationship between setting values and send/receive values, see “39.14 LFO Wave Form2
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
38.15 Flanger
Parameter Number Parameter Name Value Notes
Parameter7[1] LFO Rate 00 - 7F
Parameter7[2]
LFO Depth
00 - 7F
Parameter7[3] LFOWaveform 00 - 7F Note1
Parameter7[4] Feedback 00 - 7F
Note1 : For information about the relationship between setting values and send/receive values, see “39.14 LFO Wave Form2
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
38.16 Chorus
Parameter Number Parameter Name Value Notes
Parameter7[1] LFO Rate 00 - 7F
Parameter7[2] LFO Depth 00 - 7F
Parameter7[3] LFOWaveform 00 - 7F Note1
Parameter7[4] Feedback 00 - 7F
Parameter7[5] Type 00 - 7F Note2
Note1 : For information about the relationship between setting values and send/receive values, see “39.15 LFO Wave Form3
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
Note2 : For information about the relationship between setting values and send/receive values, see “39.10 Chorus Mode
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
91
Page view 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 110 111

Comments to this Manuals

No comments