Casio XW-G1 User Manual Page 95

  • Download
  • Add to my manuals
  • Print
  • Page
    / 111
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 94
Parameter Number Parameter Name Value Notes
Parameter7[1] WahWaveform 00 - 7F Note1
Parameter7[2] Wah Rate 00 - 7F
Parameter7[3] Wah Depth 00 - 7F
Parameter7[4] TrmWaveform 00 - 7F Note2
Parameter7[5] Trm Rate 00 - 7F
Parameter7[6] Trm Depth 00 - 7F
Note1 : For information about the relationship between setting values and send/receive values, see “39.13 LFO Wave Form1
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
Note2 : For information about the relationship between setting values and send/receive values, see “39.15 LFO Wave Form3
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
38.28 Wah Auto Pan
Parameter Number Parameter Name Value Notes
Parameter7[1] WahWaveform 00 - 7F Note1
Parameter7[2] Wah Rate 00 - 7F
Parameter7[3] Wah Depth 00 - 7F
Parameter7[4] PanWaveform 00 - 7F Note2
Parameter7[5] Pan Rate 00 - 7F
Parameter7[6] Pan Depth 00 - 7F
Parameter7[7] Pan Manual 00 - 7F Note3
Note1 : For information about the relationship between setting values and send/receive values, see “39.13 LFO Wave Form1
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
Note2 : For information about the relationship between setting values and send/receive values, see “39.15 LFO Wave Form3
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
Note3 : For information about the relationship between setting values and send/receive values, see the “39.2 –64 - 0 - +63
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
38.29 Compressor Wah
Parameter Number Parameter Name Value Notes
Parameter7[1] Cmp Thresh 00 - 7F
Parameter7[2] Cmp Level 00 - 7F
Parameter7[3] WahWaveform 00 - 7F Note1
Parameter7[4] Wah Rate 00 - 7F
Parameter7[5] Wah Depth 00 - 7F
Note1 : For information about the relationship between setting values and send/receive values, see “39.13 LFO Wave Form1
Setting Value Table” in “VIII Setting Values and Send/Receive Values” of this document.
38.30 Compressor Distortion
Parameter Number Parameter Name Value Notes
Parameter7[1] Cmp Thresh 00 - 7F
Parameter7[2] Cmp Level 00 - 7F
Parameter7[3] Dst Gain 00 - 7F
Parameter7[4] Dst Level 00 - 7F
95
Page view 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 110 111

Comments to this Manuals

No comments