Page view 13
Send Sent when the mixer part volume is changed.
Receive Receipt changes the mixer part volume.
7.6 Pan (0AH)
Message Format: BnH 0AH vvH
n: MIDI Channel Number
vv: Value(Note1)
Note1 : For information about the relationship between setting values and send/receive values, see “39.3 Pan Setting Value
Table” in “VIII Setting Values and Send/Receive Values”.
Send Sent when the pan of any part is changed.
Receive Receipt changes the pan of the corresponding part.
7.7 Expression (0BH)
Message Format: BnH 0BH vvH
n: MIDI Channel Number
vv: Value
Receive Receipt changes the Expression value.
7.8 General Use Controllers 1 through 8 (10H through 13H, 50H through
53H)
On this Instrument, these messages are used to control DSP operation.
Message Format: BnH 10H vvH DSP Parameter7[1]
BnH 11H vvH DSP Parameter7[2]
BnH 12H vvH DSP Parameter7[3]
BnH 13H vvH DSP Parameter7[4]
BnH 50H vvH DSP Parameter7[5]
BnH 51H vvH DSP Parameter7[6]
BnH 52H vvH DSP Parameter7[7]
BnH 53H vvH DSP Parameter7[8]
n: MIDI Channel Number
vv: Value
Send Sent when the drawbar rotary button is operated or when the sliders to which DSP parameters
A and B are assigned are operated.
Receive Receipt changes the value of DSP Parameter 7 [1 to 8] (7-bit parameter) assigned to the part
specified by the MIDI Channel Number. Any message received that corresponds to the parameter of a
number not being used by the currently selected DSP is ignored. For details about Parameter 7 of each
DSP, see the explanations under “VII DSP Parameter List”.