— 41 —
3. Tapping 9 voltage Write, the following display appears.
*** <AD Revision Value Write> ***
<Max Level Write>
Voltage Write-> Contacts Key
Escape -> ON Key
4. Pressing Contacts button, the following display appears.
*** <AD Revision Value Write> ***
<Max Level Write>
AD Value Read! 0x8...
<Min Level Write>
Voltage Write-> Contacts Key
Escape -> ON Key
If the unit can not read the voltage 4.2V correctly, “No Good. Please retry!!” message will appear.
Note that the unit can not be progressed in the next stage whenever this message appears.
5. Make the voltage power supply added to the main battery terminal 3.7V ± 0.05V.
Then, press Contacts button again.
Doing so, the following display appears.
*** <AD Revision Value Write> ***
<Max Level Write>
AD Value Read! 0x8...
<Min Level Write>
AD Value Read! 0x8...
<SUB Level Write>
Voltage Write-> Contacts Key
Escape -> ON Key
6. Pressing Contacts button again, the following display appears.
*** <AD Revision Value Write> ***
<Max Level Write>
AD Value Read! 0x8...
<Min Level Write>
AD Value Read! 0x8...
<SUB Level Write>
AD Value Read! 0x8...
Write Data Value
Max=0x... Sub=0x...
Min=0x...
-----------→ Test END
Push Action Key
7. Pressing Action Control button, the following display appears along with Main Menu display.
AD Code=OOOOO
CPROG Rev.1.01 for JX-650
If missed, the following # displays appear instead of O.
AD Code=# # # # #
CPROG Rev.1.01 for JX-650
Comments to this Manuals