3-6
Using Advanced Setup
4. To change the number of samples setting, move the highlighting to “Number”. Next, press
1 to display a dialog box for specifying the number of samples.
• The total sampling time shown at the bottom of the dialog box is calculated by multiply-
ing the “Sampling Interval” value you specified in step 3 by the number of samples you
specify here.
Important!
• When all of the following conditions exist, a “Distance” setting appears in place of the
“Number” setting. See “To configure the Distance setting” (page 3-7) for information
about confi
guring the “Distance” setting.
• Channel Setup (page 3-3): 2(VRNR) - [Photogate] - [Pulley]
• Sampling Mode (page 3-5): Clock
5. To change the warm-up time setting, move the highlighting to “Warm-up”. Next, perform
one of the function key operations described below.
Note
• The “Warm-up” setting will not be displayed on the Sample Setup screen if “Fast”,
“Sound” or “Extended” is currently selected as the sampling mode.
Important!
• When the following condition exists, an “FFT Graph” setting appears in place of the
“Warm-up” setting. See “To configure the FFT Graph setting” (page 3-7) for information
about configuring the “FFT Graph” setting.
• Sampling Mode (page 3-5): Fast
To do this: Press this key:
Have the warm-up time for each sensor set automatically 1 (Auto)
Input a warm-up time, in seconds, manually 2 (Man)
Disable the warm-up time 3 (None)
3. To change the sampling interval setting, move the highlighting to “Interval”. Next, press
1 to display a dialog box for specifying the sampling interval.
• The range of values you can select depends on the current sampling mode setting.
If this sampling mode is selected: This is the allowable setting range:
Realtime 0.2 to 299 sec
Fast 20 to 500
μ
sec
Extended 5 to 240 min
Period “=Trigger” only (no value input required)
Sound 20 to 27
μ
sec
Clock “=Trigger” only (no value input required)
Normal 0.0005 to 299 sec